Properties of hybrid fiber reinforced concrete under repeated impact loads

dc.contributor.authorYildirim, S. Taner
dc.contributor.authorEkinci, Cevdet E.
dc.contributor.authorFindik, Fehim
dc.date.accessioned2026-08-12T17:14:25Z
dc.date.issued2010
dc.departmentFırat Üniversitesi
dc.description.abstractSteel, glass and polypropylene fiber reinforced concrete structures were investigated under repeated impact loads in this study. Twelve different concrete series prepared fiberless the one of all and the others reinforced polypropylene, glass, steel and hybrid fiber were produced. The polypropylene fibers in diameter of 50 mm, l/d (length/diameter) ratio of 400, glass fibers in diameter of 14 mm, l/d ratio of 857 and steel fibers in diameter of 0.75 mm, l/d ratio of 80 were used in concrete mixtures. The volumetric contents were 0.5, 0.75 and 1% in fiber reinforced concrete. The volumetric content was 0.1% in polypropylene and glass fiber reinforced concrete. Drop-weight test similar the method presented ACI 544.2R-89 was conducted using 28 days cured samples having dimensions of 100 x 100 x 100 mm and reduction of strength were determined by ultrasonic pulse velocity (UPV) test. Furthermore, initial crack formation and fracture numbers variation in samples were detected. In the present study, it was aimed to develop performance under repeated impact loads using fibers in concrete. As a result, especially impact performance was rather increased in steel fiber reinforced concrete, and hybrid fibers had also positive effect on the performance of concrete.
dc.identifier.doi10.1134/S1061830910070090
dc.identifier.endpage546
dc.identifier.issn1061-8309
dc.identifier.issn1608-3385
dc.identifier.issue7
dc.identifier.orcid0000-0003-0021-0625
dc.identifier.orcid0000-0003-2537-1951
dc.identifier.scopus2-s2.0-78649953705
dc.identifier.scopusqualityQ3
dc.identifier.startpage538
dc.identifier.urihttps://doi.org/10.1134/S1061830910070090
dc.identifier.urihttps://hdl.handle.net/11508/51823
dc.identifier.volume46
dc.identifier.wosWOS:000284167300009
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPleiades Publishing Inc
dc.relation.ispartofRussian Journal of Nondestructive Testing
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectSteel
dc.subjectglass and polypropylene fiber
dc.subjecthybrid fibered concrete
dc.subjectdrop-weight test
dc.subjectrepeated impact loads
dc.titleProperties of hybrid fiber reinforced concrete under repeated impact loads
dc.typeArticle

Dosyalar