The effect of length of free-surface gated circular conduit on air-demand ratio and aeration efficiency

dc.contributor.authorOzkan, Fahri
dc.contributor.authorDemirel, Ibrahim Halil
dc.contributor.authorTuna, Muhammed Cihat
dc.contributor.authorBaylar, Ahmet
dc.date.accessioned2026-08-12T16:40:32Z
dc.date.issued2015
dc.departmentFırat Üniversitesi
dc.description.abstractAeration is the process of bringing water and air into close contact in order to increase dissolved oxygen concentration. The concentration of dissolved oxygen is an important indicator of water quality because aquatic life lives on the dissolved oxygen in the water. The hydraulic structures can be accepted as the key components in increasing dissolved oxygen concentration because of the strong turbulent mixing associated with substantial air bubble entrainment at these structures. Closed conduit is a classic example of a hydraulic structure where aeration occurs. This work focused on determining the effect of conduit length on air-demand ratio and aeration efficiency in free-surface gated circular conduits. Experimental results showed that the Froude number had an important effect on the air-demand ratio and the aeration efficiency. The effect of the conduit length on the air-demand ratio and the aeration efficiency changed depending on the Froude number. It was demonstrated from the results that a free-surface gated circular conduit flow system had high efficiency in transferring oxygen from air bubbles to water. Moreover, a formula for the aeration efficiency was presented relating the aeration efficiency to the conduit length and the Froude number.
dc.identifier.doi10.2166/ws.2015.081
dc.identifier.endpage1192
dc.identifier.issn1606-9749
dc.identifier.issue6
dc.identifier.orcid0000-0003-2594-0114
dc.identifier.orcid0000-0002-8226-6034
dc.identifier.orcid0000-0002-4932-9443
dc.identifier.scopus2-s2.0-84960860767
dc.identifier.scopusqualityQ2
dc.identifier.startpage1187
dc.identifier.urihttps://doi.org/10.2166/ws.2015.081
dc.identifier.urihttps://hdl.handle.net/11508/45446
dc.identifier.volume15
dc.identifier.wosWOS:000374302500004
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherIwa Publishing
dc.relation.ispartofWater Science and Technology-Water Supply
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectaeration efficiency
dc.subjectair-demand ratio
dc.subjectconduit
dc.subjectfree-surface flow
dc.subjectoxygen transfer
dc.titleThe effect of length of free-surface gated circular conduit on air-demand ratio and aeration efficiency
dc.typeArticle

Dosyalar