An estimation of the performance of a passive cooling system incorporating a ground heat exchanger using a multilayer artificial neural network

dc.contributor.YOKID59286
dc.contributor.YOKID59908
dc.contributor.authorTutumlu, Hakan
dc.contributor.authorDuman, Erkan
dc.contributor.authorInalli, Mustafa
dc.date.accessioned2022-09-05T11:59:04Z
dc.date.available2022-09-05T11:59:04Z
dc.date.issued2022-06-28
dc.descriptionMakale - Bilimsel Dergi Makalesi - Çok Yazarlı
dc.description.abstractAbstract Objective: This paper examines the cooling of an office building without a heat pump, using only ground heat exchangers (GHE) and implementing artificial neural network (ANN) to train it on experimental data. Methods: The office building is situated at 38° 40? 57?? N latitude and 39° 10? 29?? E longitude in the province of Elazig. Each minute, the installed system was monitoring the office’s external meteorological data, the office’s indoor meteorological data, the GHE inlet and outlet temperatures, and the amount of heat load developed during the cooling process. In this study, the passive cooling system’s cooling load and coefficient of performance (COP) were experimentally examined. A second important contribution of this paper is the multilayer ANN model that was created using data selected from the experimental setup, which was measured and recorded. Results: During the summer months of 2018, the COP of the system was measured to be 1.67 on average. The accuracy rates of the multilayer ANN model proposed for cooling systems were calculated to be over 99% and 95% in the training and test datasets, respectively. It was observed that the performance value estimated by ANN converges to the true value by 99%. Conclusion: Having performed this study, it has been demonstrated that passive cooling can be achieved with GHE, and by conducting this study without utilizing a heat pump system, we intend to contribute significantly to the relevant scientific literature.
dc.identifier.citationTutumlu, H., Duman, E. ve Inalli, M. (2022). An estimation of the performance of a passive cooling system incorporating a ground heat exchanger using a multilayer artificial neural network. Journal of Modern Green Energy, 1(1), 1-12.
dc.identifier.doi10.53964/jmge.2022001
dc.identifier.endpage12
dc.identifier.issue1
dc.identifier.startpage1
dc.identifier.urihttp://hdl.handle.net/11508/21022
dc.identifier.volume1
dc.language.isoen
dc.relation.ispartofJournal of Modern Green Energy
dc.relation.publicationcategoryUluslararası
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGround heat exchanger
dc.subjectPassive cooling
dc.subjectMultilayer artificial neural network
dc.subjectCoefficient of performance estimation
dc.titleAn estimation of the performance of a passive cooling system incorporating a ground heat exchanger using a multilayer artificial neural network
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
JMGE20220067.pdf
Boyut:
4,81 MB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
14,1 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: