EXPERIMENTAL AND NUMERICAL COMPARISON OF THERMODYNAMIC PERFORMANCES OF NEW AND OLD GENERATION REFRIGERANTS IN THE SAME COOLING SYSTEM

dc.contributor.authorDas, Mehmet
dc.contributor.authorPektezel, Oguzhan
dc.date.accessioned2026-08-12T17:07:05Z
dc.date.issued2022
dc.departmentFırat Üniversitesi
dc.description.abstractThe use of new generation low GWP refrigerants in cooling systems is becoming increasingly common due to thermal performance and less environmental impact. In this study, the thermal performance of the new generation R290 refrigerant and the old generation R404A refrigerant in the same cooling system were investigated experimentally and numerically. The thermal performance values of both gases were compared, provided that the temperature of the cold room cooled by the vapor compression cooling system drops to 0 degrees C. -5 degrees C, 0 degrees C, 5 degrees C evaporator temperatures and 25 degrees C, 30 degrees C, 35 degrees C condenser temperatures were used as operating parameters. The experimental results revealed that the highest COP values in the system for R290 and R404A were 4.68 and 3.94, respectively. An average of 9.38% increase in cooling capacity was detected with R290 compared to R404A refrigerant. In the numerical analysis part of the study, the evaporator surface temperature and air velocity distributions of both refrigerants in the cold room were shown numerically by using ANSYS FLUENT 19.1. As a result of the study, it was stated that R290 had higher thermal performance than R404A, according to both experimental and numerical analysis results.
dc.description.sponsorshipTokat Gaziosmanpasa University Scientific Research Foundation [2020/122]
dc.description.sponsorshipAuthors would like to thank Tokat Gaziosmanpasa University Scientific Research Foundation for supporting this study with the project number of 2020/122.
dc.identifier.doi10.2298/TSCI220205069D
dc.identifier.endpage4854
dc.identifier.issn0354-9836
dc.identifier.issn2334-7163
dc.identifier.issue6
dc.identifier.scopus2-s2.0-85143850087
dc.identifier.scopusqualityQ3
dc.identifier.startpage4841
dc.identifier.urihttps://doi.org/10.2298/TSCI220205069D
dc.identifier.urihttps://hdl.handle.net/11508/49517
dc.identifier.volume26
dc.identifier.wosWOS:000908419600028
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherVinca Inst Nuclear Sci
dc.relation.ispartofThermal Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectcold room
dc.subjectR290
dc.subjectthermal performance
dc.subjectCOP
dc.subjectCFD analysis
dc.titleEXPERIMENTAL AND NUMERICAL COMPARISON OF THERMODYNAMIC PERFORMANCES OF NEW AND OLD GENERATION REFRIGERANTS IN THE SAME COOLING SYSTEM
dc.typeArticle

Dosyalar