Removal of hydrogen chloride from flue gases with calcined limestone particles in a fixed bed reactor

dc.contributor.authorAkosman, C
dc.contributor.authorWalters, JK
dc.date.accessioned2026-08-12T16:34:30Z
dc.date.issued2003
dc.departmentFırat Üniversitesi
dc.description.abstractThe sorption of hydrogen chloride gas (HCl) on fully calcined commercial limestone particles was experimentally investigated using a fixed bed reactor at temperatures between 400-650 degreesC. The gas phase was a mixture of HCl and N-2 with an inlet HCl concentration of 0.5% mol. The limestone particles were diluted in inert mullite beads to obtain a proper gas-solid contact. The experimental results showed that the conversion of solids increased with increasing temperature. Also HCl removal efficiency increased with increase in temperature and limestone quantity in the bed.
dc.identifier.endpage1535
dc.identifier.issn1018-4619
dc.identifier.issue12
dc.identifier.scopus2-s2.0-1642424186
dc.identifier.scopusqualityN/A
dc.identifier.startpage1530
dc.identifier.urihttps://hdl.handle.net/11508/44475
dc.identifier.volume12
dc.identifier.wosWOS:000188392900014
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherParlar Scientific Publications (P S P)
dc.relation.ispartofFresenius Environmental Bulletin
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectHCl removal
dc.subjectfixed bed
dc.subjectgas cleaning
dc.subjectlimestone utilisation
dc.titleRemoval of hydrogen chloride from flue gases with calcined limestone particles in a fixed bed reactor