NUMERICAL INVESTIGATION OF RELIABILITY OF PUMP SYSTEMS FROM THERMAL POWER PLANTS

dc.contributor.authorBugatekin, Ayse T.
dc.date.accessioned2026-08-12T17:05:01Z
dc.date.issued2018
dc.departmentFırat Üniversitesi
dc.description.abstractThis article deals with numerical investigation of reliability of pump systems from thermal power plants. The reliability is examined by using intensity function for a system composed of n-linearly ordered pumps. The time between failures of pumps is taken as experimental. Firstly, appropriate model for the data is determined. Estimates of parameters are obtained with maximum likelihood method and intensity function models are written. Finally, reliability of consecutive 3-out-of-5:F systems are calculated for certain time periods by using the obtained intensity functions.
dc.identifier.doi10.2298/TSCI170612279B
dc.identifier.endpageS142
dc.identifier.issn0354-9836
dc.identifier.issn2334-7163
dc.identifier.orcid0000-0001-8949-8367
dc.identifier.scopus2-s2.0-85046859395
dc.identifier.scopusqualityQ3
dc.identifier.startpageS137
dc.identifier.urihttps://doi.org/10.2298/TSCI170612279B
dc.identifier.urihttps://hdl.handle.net/11508/48952
dc.identifier.volume22
dc.identifier.wosWOS:000431094700016
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherVinca Inst Nuclear Sci
dc.relation.ispartofThermal Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectreliability
dc.subjecttime between failure
dc.subjectpower law model
dc.subjectmaximum likelihood method
dc.titleNUMERICAL INVESTIGATION OF RELIABILITY OF PUMP SYSTEMS FROM THERMAL POWER PLANTS
dc.typeArticle

Dosyalar