Effect of Application Time of Two Different Disinfectants on the Surface Roughness of an Elastomeric Impression Material

dc.contributor.authorKaraman, Tahir
dc.contributor.authorOztekin, Faruk
dc.contributor.authorTekin, Samet
dc.date.accessioned2026-08-12T17:08:10Z
dc.date.issued2020
dc.departmentFırat Üniversitesi
dc.description.abstractIntroduction: Pathogens, such as cytomegalovirus, hepatitis B virus, hepatitis C virus, herpes simplex virus types 1 and 2, and human immunodeficiency virus, are transmitted, threatening the health of dental laboratory workers, especially as a result of saliva and blood contact of patients. To prevent cross-infection, impression materials should be disinfected at the end of the impression process in the mouth. Aim: To study the effect of application time of sodium hypochlorite and quaternary ammonium-based disinfectant solution on the surface roughness of an elastomeric impression material. Materials and Methods: In this in-vitro study done during March 2020, 10 disc-shaped samples were used in each group, with a total of 110 samples obtained from a light body elastomeric impression material with dimensions of 15x3 mm. The samples were kept in a sodium hypochlorite solution (Wizard; Rehber Kimya, Istanbul, Turkey) at concentrations of 1% and 5% for 1, 5, 10, and 30 minutes and in a quaternary ammonium-based disinfectant (Zeta 7 Solution, Zhermack SpA, Italy) for 10 and 30 minutes. Surface roughness measurements were taken with a profilometer device. The data obtained were statistically analysed by Kolmogorov-Smirnov test and Wilcoxon signed rank test for dependent/paired groups for the continuous data. The significance level was set to alpha=0.05. Results: A statistically significant difference was found between the control group and the 1% sodium hypochlorite (30 min p-value 0.037), and 5% sodium hypochlorite (30 min p-value 0.017). The statistical evaluation of the surface roughness of the samples with different concentrations of sodium hypochlorite and the same times was done and found statistically significant at 30 mins. p-value 0.021. Conclusion: The prolonged application of the sodium hypochlorite disinfectant at 1% and 5% concentrations caused a significant increase in the light body elastomeric impression material's surface roughness.
dc.identifier.doi10.7860/JCDR/2020/44752.13828
dc.identifier.endpageZC13
dc.identifier.issn2249-782X
dc.identifier.issn0973-709X
dc.identifier.issue7
dc.identifier.orcid0000-0001-8883-8307
dc.identifier.orcid0000-0002-5131-0063
dc.identifier.startpageZC10
dc.identifier.urihttps://doi.org/10.7860/JCDR/2020/44752.13828
dc.identifier.urihttps://hdl.handle.net/11508/49952
dc.identifier.volume14
dc.identifier.wosWOS:000551009800058
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherPremchand Shantidevi Research Foundation
dc.relation.ispartofJournal of Clinical and Diagnostic Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectAmmonium-based disinfectant
dc.subjectChemical disinfection
dc.subjectCross-infection
dc.subjectDisinfection times
dc.subjectSodium hypochlorite
dc.titleEffect of Application Time of Two Different Disinfectants on the Surface Roughness of an Elastomeric Impression Material
dc.typeArticle

Dosyalar