Influence of drill parameters on bone temperature and necrosis: A FEM modelling and in vitro experiments

dc.contributor.authorSezek, S.
dc.contributor.authorAksakal, B.
dc.contributor.authorKaraca, F.
dc.date.accessioned2026-08-12T17:31:35Z
dc.date.issued2012
dc.departmentFırat Üniversitesi
dc.description.abstractDuring drilling of bone, excessive heat may cause thermonecrosis and this weakens the purchase of surgically placed screws and pins thus reduces the success of subsequent fixation and implantation process. In order to minimise the problems caused by high temperature (above 45 degrees C) in bone drilling operations, it is necessary to operate with optimum cutting and drilling parameters. This study analysis the temperature changes during cortical bone drilling for different parameters such as drill rotation speed, feed-rate, drill diameter, drill force, bone mineral density and bone sex via the finite element method, FEM. The analysis have been validated by in vitro experiments using fresh calf cortical bones. Analytical and experimental results showed that the safe drilling parameters and drill temperatures can be estimated. To avoid thermal necrosis, the safe drilling zones (below 45 degrees C) have been determined for various drill parameters during drilling of fresh cortical bones. Temperature increased 10% with 12% increase in bone mineral density and the safe drill parameters obtained to be 370 rpm drill speed, 70 mm/min feed rate and 140 N drill force. (C) 2012 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.commatsci.2012.03.012
dc.identifier.endpage18
dc.identifier.issn0927-0256
dc.identifier.issn1879-0801
dc.identifier.orcid0000-0002-4614-3723
dc.identifier.orcid0000-0003-4844-9387
dc.identifier.orcid0009-0007-7644-5785
dc.identifier.orcid0000-0003-1874-9274
dc.identifier.scopus2-s2.0-84860500041
dc.identifier.scopusqualityQ1
dc.identifier.startpage13
dc.identifier.urihttps://doi.org/10.1016/j.commatsci.2012.03.012
dc.identifier.urihttps://hdl.handle.net/11508/56319
dc.identifier.volume60
dc.identifier.wosWOS:000303657700003
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofComputational Materials Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectOrthopaedics
dc.subjectBone drilling
dc.subjectThermal necrosis
dc.subjectFEM
dc.titleInfluence of drill parameters on bone temperature and necrosis: A FEM modelling and in vitro experiments
dc.typeArticle

Dosyalar