Heat transfer and sensitivity analysis in a double pipe heat exchanger filled with porous medium

dc.contributor.authorShirvan, Kamel Milani
dc.contributor.authorMirzakhanlari, Soroush
dc.contributor.authorKalogirou, Soteris A.
dc.contributor.authorÖztop, Hakan Fehmi
dc.contributor.authorMamourian, Mojtaba
dc.date.accessioned2026-08-12T17:49:12Z
dc.date.issued2017
dc.departmentFırat Üniversitesi
dc.description.abstractIn this paper, 2-D numerical investigation and sensitivity analysis are performed on heat transfer rate and heat exchanger effectiveness of a double pipe heat exchanger filled with porous medium. The Darcy -Brinkman-Forchheimer model is applied to model the flow field in the porous zone. The sensitivity analysis is performed utilizing the Response Surface Methodology. The studied parameters are: Reynolds number (50 <= Re <= 250), Darcy number (10(-5) <= Da <= 10(-3)), temperature difference between hot and cold fluids (30 <= Delta T <= 70) and the porous substrate thickness (1/3 <= delta <= 1). The obtained results showed that enhancement of the Nusselt number due to the increase in Reynolds and Darcy numbers is in the vicinity of the 77.84% for the case with delta = 2/3 and Da =10(-5) to 10(-3), and 203.25% for the case with delta =1 and Re = 50 to 250. Furthermore, increasing porous substrate thickness reduces the mean Nusselt number until delta = 2/3 and then increases it. In addition, it is found that the heat exchanger effectiveness increases with the Re number and reduces with enhancement of the Da number. The sensitivity analysis showed that the sensitivity of the mean Nusselt number to the Re and Da numbers and the porous substrate thickness is positive, while the sensitivity of the heat exchanger effectiveness to the Re number is positive but to the Da number is negative. (C) 2017 Elsevier Masson SAS. All rights reserved.
dc.identifier.doi10.1016/j.ijthermalsci.2017.07.008
dc.identifier.endpage137
dc.identifier.issn1290-0729
dc.identifier.issn1778-4166
dc.identifier.orcid0000-0002-3654-1437
dc.identifier.orcid0000-0002-7967-0511
dc.identifier.scopus2-s2.0-85025077929
dc.identifier.scopusqualityQ1
dc.identifier.startpage124
dc.identifier.urihttps://doi.org/10.1016/j.ijthermalsci.2017.07.008
dc.identifier.urihttps://hdl.handle.net/11508/61721
dc.identifier.volume121
dc.identifier.wosWOS:000411535100010
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier France-Editions Scientifiques Medicales Elsevier
dc.relation.ispartofInternational Journal of Thermal Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectResponse surface methodology
dc.subjectSensitivity analysis
dc.subjectHeat exchanger effectiveness double pipe
dc.subjectheat exchanger
dc.subjectHeat transfer
dc.subjectPorous medium
dc.titleHeat transfer and sensitivity analysis in a double pipe heat exchanger filled with porous medium
dc.typeArticle

Dosyalar