Cr(VI) reduction in aqueous solutions by using pyrite

dc.contributor.authorErdem, Mehmet
dc.contributor.authorTümen, Fikret
dc.date.accessioned2026-08-12T16:12:48Z
dc.date.issued1996
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, the effects of the amount of acid, pyrite dosage, contact time, initial Cr(VI) concentration, temperature and pyrite particle size on the Cr(VI) reduction in the aqueous solution by using pyrite were investigated. The Cr(VI) in the concentration range of 80-150 mg/l has been effectively reduced within a contact period of 75 min with the pyrite at the 10 g/l dosage and -270 mesh particle size in the solution containing twice as much of the stoichiometric amount of H2SO4. Results have shown that pyrite is an effective reductant but its reduction capacity is low compared to theoretical calculations.:.
dc.identifier.endpage369
dc.identifier.issn1300-0160
dc.identifier.issue6
dc.identifier.scopus2-s2.0-0000548051
dc.identifier.scopusqualityN/A
dc.identifier.startpage363
dc.identifier.urihttps://hdl.handle.net/11508/42652
dc.identifier.volume20
dc.indekslendigikaynakScopus
dc.language.isotr
dc.relation.ispartofTurkish Journal of Engineering and Environmental Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_Scopus_20260511
dc.subjectChromium; Cr(VI) reduction; Heavy metal removal; Pyrite
dc.titleCr(VI) reduction in aqueous solutions by using pyrite
dc.title.alternativePirit kullanilarak sulu çözeltilerde CR(VI) i?ndirgenmesi
dc.typeArticle

Dosyalar