Numerical analysis of the effect of implant geometry to stress distributions of the three different commercial dental implant system

dc.contributor.authorTopkaya, Tolga
dc.contributor.authorSolmaz, Murat Yavuz
dc.contributor.authorDündar, Serkan
dc.contributor.authorEltas, Abubekir
dc.date.accessioned2026-08-12T16:07:39Z
dc.date.issued2015
dc.departmentFırat Üniversitesi
dc.description.abstractObjectives: The success of dental implants is related to the quality, quantity of local bones, implant design and surgical technique. Implant diameter and length are accepted as key factors. Present work focuses to investigate the effect of titanium implant geometry to stress distributions in implant system. Materials and Methods: For this purpose three different implant models which are currently being used in clinical cases constructed by using ANSYS Workbench 12.1. The stress distributions on components of implant system under static loadings were analyzed for all models. Results: The maximum stress values that occurred in all components happen in the case of loading in which the Nucleoss T-4 (Nucleoss, Turkiye) implant is used, but the occurred lowest stress values happen in the case of Fi loading in which Nobel Active (Nobel Biocare, Zurich, Switzerland) implant is used. In all models, the maximum tensions have occurred in the neck region of the implants. Conclusions: The crestal bone loss in the neck region of the implants reduced the long-term survival rate of implants.The length and the size of the implant are the two important factors in the stress distribution.
dc.identifier.doi10.7126/cdj.58140.5000037693
dc.identifier.endpage24
dc.identifier.issn2146-2852
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84922762859
dc.identifier.scopusqualityQ4
dc.identifier.startpage17
dc.identifier.trdizinid175453
dc.identifier.urihttps://doi.org/10.7126/cdj.58140.5000037693
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/175453
dc.identifier.urihttps://hdl.handle.net/11508/40838
dc.identifier.volume18
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherCumhuriyet University Faculty of Dentistry
dc.relation.ispartofCumhuriyet Dental Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_Scopus_20260511
dc.subjectDental implant design; Finite element analysis; Stress distribution
dc.titleNumerical analysis of the effect of implant geometry to stress distributions of the three different commercial dental implant system
dc.typeReview Article

Dosyalar