| dc.description.abstract | A predictive theory is presented which is capable of providing quantitative results for the heat transfer in impinging co-axial jets for the turbulent flow regime. The numerical solution is performed by making use of the CFX software package which discretizes the solution domain into quadrilateral elements. The heat transfer is calculated with the Nusselt number. The geometric variable parameter is the diameter ratio d/D (ratio of inner diameters of the inner and outer pipes). Other dependent parameters are dimensionless jet-to-impingement plate distance (H/D), Reynolds number (Re), and dimensionless radial distance (r/D). Local, average, and stagnation-point Nusselt numbers were found as the results of heat transfer analysis. It was found that local, average, and stagnation-point heat transfer with d/D attained a maximum at d/D = 0.55. For d/D = 0.55 and 0.35, for a given Reynolds number (10,000, 20,000, and 50,000), a co-axial jet yields higher heat transfer coefficients than a single jet. | |
| dc.description.sponsorship | TUBITAK (The Scientific and Technological Research Council of Turkey) | |
| dc.description.sponsorship | We would like to express our gratitude to TUBITAK (The Scientific and Technological Research Council of Turkey) for supplying financial funding to the first author of this paper, to do her Post-Doctoral Research at the University of Minnesota. Also, we would like to thank our advisor, Professor E. M. Sparrow, for his consultancy and all contributions to this investigation. | |
| dc.identifier.doi | 10.1615/JEnhHeatTransf.2012002414 | |
| dc.identifier.endpage | 147 | |
| dc.identifier.issn | 1065-5131 | |
| dc.identifier.issn | 1563-5074 | |
| dc.identifier.issue | 2 | |
| dc.identifier.orcid | 0000-0003-2456-5316 | |
| dc.identifier.scopus | 2-s2.0-84860449607 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 135 | |
| dc.identifier.uri | https://doi.org/10.1615/JEnhHeatTransf.2012002414 | |
| dc.identifier.uri | https://hdl.handle.net/11508/51977 | |
| dc.identifier.volume | 19 | |
| dc.identifier.wos | WOS:000302839200004 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Begell House Inc | |
| dc.relation.ispartof | Journal of Enhanced Heat Transfer | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260511 | |
| dc.subject | co-axial jet | |
| dc.subject | numerical analysis | |
| dc.subject | impingement | |
| dc.title | NUMERICAL INVESTIGATION OF THE CO-AXIAL IMPINGING JETS WITH VARIOUS DIAMETER RATIOS | |
| dc.type | Article |