Heat transfer enhancement in circular tubes using helical swirl generator insert at the entrance
| dc.contributor.author | Gul, H. | |
| dc.contributor.author | Evin, D. | |
| dc.date.accessioned | 2026-08-12T17:44:59Z | |
| dc.date.issued | 2007 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | This paper presents an experimental study of heat transfer and friction characteristics in decaying turbulent swirl flow generated by a short helical tape placed at the entrance of the test section. In the experiments, total mass flux was varied from 160 kg m(-2) s(-1) to 1628 kg m(-2) s(-1) and the momentum ratio (M-h/M-T) was varied from 0 to 8.6. The experiments were conducted for water flow rates in the range of 5000 <= Re <= 30 000. Three different helical tapes with helical angels of 30 degrees, 45 degrees and 60 degrees were used. Experimental results confirm that, the use of a helical tape inserted to the tube leads to a higher heat transfer rate than the non-swirling flow. The local heat transfer coefficients were found to be increasing to very high values along the downstream of the helical tape, and then decreasing with the distance (x/L). The augmentation of heat transfer was found to be the function of the momentum ratio, M-h/M-T and Reynolds number. No pronounced effect of the number of the helical channels (N-h), and helical angle (alpha) on heat transfer was observed. It is found that using the helical tape can help to increase the heat transfer rate up to 20% depending on M-h/M-T and Re at constant pumping power. Enhancement efficiency increases with increasing momentum ratio and decreases with increasing Reynolds number. (C) 2007 Elsevier Masson SAS. All rights reserved. | |
| dc.identifier.doi | 10.1016/j.ijthermalsci.2006.12.010 | |
| dc.identifier.endpage | 1303 | |
| dc.identifier.issn | 1290-0729 | |
| dc.identifier.issn | 1778-4166 | |
| dc.identifier.issue | 12 | |
| dc.identifier.scopus | 2-s2.0-35148874713 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 1297 | |
| dc.identifier.uri | https://doi.org/10.1016/j.ijthermalsci.2006.12.010 | |
| dc.identifier.uri | https://hdl.handle.net/11508/60496 | |
| dc.identifier.volume | 46 | |
| dc.identifier.wos | WOS:000250930500011 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Elsevier France-Editions Scientifiques Medicales Elsevier | |
| dc.relation.ispartof | International Journal of Thermal Sciences | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260511 | |
| dc.subject | heat transfer enhancement | |
| dc.subject | circular tubes | |
| dc.subject | swirl flow | |
| dc.subject | helical tape | |
| dc.title | Heat transfer enhancement in circular tubes using helical swirl generator insert at the entrance | |
| dc.type | Article |