Finite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implants

dc.contributor.authorDundar, Serkan
dc.contributor.authorTopkaya, Tolga
dc.contributor.authorSolmaz, Murat Yavuz
dc.contributor.authorYaman, Ferhan
dc.contributor.authorAtalay, Yusuf
dc.contributor.authorSaybak, Arif
dc.contributor.authorCakmak, Omer
dc.date.accessioned2026-08-12T17:04:28Z
dc.date.issued2016
dc.departmentFırat Üniversitesi
dc.description.abstractThe aim of this study was to examine the stress distributions with three different loads in two different geometric and threaded types of dental implants by finite element analysis. For this purpose, two different implant models, Nobel Replace and Nobel Active (Nobel Biocare, Zurich, Switzerland), which are currently used in clinical cases, were constructed by using ANSYS Workbench 12.1. The stress distributions on components of the implant system under three different static loadings were analysed for the two models. The maximum stress values that occurred in all components were observed in F-III (300 N). The maximum stress values occurred in F-III (300 N) when the Nobel Replace implant is used, whereas the lowest ones, in the case of F-I (150 N) loading in the Nobel Active implant. In all models, the maximum tensions were observed to be in the neck region of the implants. Increasing the connection between the implant and the bone surface may allow more uniform distribution of the forces of the dental implant and may protect the bone around the implant. Thus, the implant could remain in the mouth for longer periods. Variable-thread tapered implants can increase the implant and bone contact.
dc.identifier.doi10.1080/13102818.2015.1083887
dc.identifier.endpage133
dc.identifier.issn1310-2818
dc.identifier.issn1314-3530
dc.identifier.issue1
dc.identifier.orcid0000-0001-6394-0313
dc.identifier.orcid0000-0001-6650-8067
dc.identifier.orcid0000-0003-3252-5867
dc.identifier.scopus2-s2.0-84956862565
dc.identifier.scopusqualityQ3
dc.identifier.startpage127
dc.identifier.urihttps://doi.org/10.1080/13102818.2015.1083887
dc.identifier.urihttps://hdl.handle.net/11508/48734
dc.identifier.volume30
dc.identifier.wosWOS:000369854400018
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTaylor & Francis Ltd
dc.relation.ispartofBiotechnology & Biotechnological Equipment
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectFinite element analysis
dc.subjectdental implant design
dc.subjectstress distribution
dc.subjectoblique loading
dc.subjectthread design
dc.titleFinite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implants
dc.typeArticle

Dosyalar