Evaluation of liver hemangiomas using three different b values on diffusion MR
| dc.contributor.author | Bozgeyik, Zulkif | |
| dc.contributor.author | Kocakoc, Ercan | |
| dc.contributor.author | Gul, Yeliz | |
| dc.contributor.author | Dagli, A. Ferda | |
| dc.date.accessioned | 2026-08-12T17:46:05Z | |
| dc.date.issued | 2010 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | Purpose: To determine which diffusion-weighted MR technique (i.e., b-100, b-600, b-1000s/mm(2)) is most useful in depicting liver hemangiomas. We also aimed to assess the effect of lesion size on apparent diffusion coefficient (ADC) values. Materials and methods: Diffusion-weighed MR (DWMR) was performed for 61 hemangiomas in 32 patients. DWMR images were obtained before contrast administration using three different b values of 100, 600, and 1000s/mm(2). ADCs were measured for each lesions and compared with normal liver parenchymal ADCs on different b values. Hemangiomas were subdivided according to lesion size (less than 3 cm and 3 cm or greater). Data were analyzed using SPSS software by analysis of variances (ANOVA) and post hoc values were tested using HSD Tukey test. Results: There was no significant relation between lesion size and ADC values on different b values. Lower ADC values were obtained for higher b values in normal liver tissue and hemangiomas. Although there is significant difference between normal liver tissue and hemangiomas; this is more apparent on b-1000 images (p = 0.022 on b-100, p = 0.003 on b-600, and p = 0.000 on b-1000 images). Variance analysis revealed hemangiomas had higher ADC values than normal liver tissue on b-1000 images. Conclusion: Mean values for ADCs of hemangiomas were lower than ADCs of the normal liver except for b-1000 value. Higher b values are useful for the differentiation between normal liver tissue and hemangiomas. Lesion size does not affect ADC measurement on different b values. (C) 2009 Elsevier Ireland Ltd. All rights reserved. | |
| dc.identifier.doi | 10.1016/j.ejrad.2009.04.065 | |
| dc.identifier.endpage | 363 | |
| dc.identifier.issn | 0720-048X | |
| dc.identifier.issue | 3 | |
| dc.identifier.orcid | 0000-0001-9280-3254 | |
| dc.identifier.pmid | 19481893 | |
| dc.identifier.scopus | 2-s2.0-77956968573 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 360 | |
| dc.identifier.uri | https://doi.org/10.1016/j.ejrad.2009.04.065 | |
| dc.identifier.uri | https://hdl.handle.net/11508/60947 | |
| dc.identifier.volume | 75 | |
| dc.identifier.wos | WOS:000282365900015 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Ireland Ltd | |
| dc.relation.ispartof | European Journal of Radiology | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260511 | |
| dc.subject | Liver | |
| dc.subject | Hemangioma | |
| dc.subject | DWI | |
| dc.subject | Diffusion-weighted MRI | |
| dc.subject | MRI | |
| dc.title | Evaluation of liver hemangiomas using three different b values on diffusion MR | |
| dc.type | Article |







