Determination of As, Cd, and Pb in Tap Water and Bottled Water Samples by Using Optimized GFAAS System with Pd-Mg and Ni as Matrix Modifiers

dc.contributor.authorBakirdere, Sezgin
dc.contributor.authorYaroglu, Tolga
dc.contributor.authorTirik, Nihan
dc.contributor.authorDemiroz, Mehmet
dc.contributor.authorFidan, A. Kemal
dc.contributor.authorMaruldali, Onur
dc.contributor.authorKaraca, Abdullah
dc.date.accessioned2026-08-12T17:31:50Z
dc.date.issued2013
dc.departmentFırat Üniversitesi
dc.description.abstractArsenic, lead and cadmium were determined in tap and bottled water samples consumed in the west part of Turkey at trace levels. Graphite Furnace Atomic Absorption Spectrometry (GFAAS) was used in all detections. All of the system parameters for each element were optimized to increase sensitivity. Pd-Mg mixture was selected as the best matrix modifier for As while the highest signals were obtained for Pb and Cd in the case of Ni used as matrix modifier. Detection limits for As, Cd, and Pb were found to be 2.0, 0.036 and 0.25 ng/mL, respectively. 78 tap water and 17 different brands of bottled water samples were analyzed for their As, Cd and Pb contents under the optimized conditions. In all water samples, concentration of cadmium was found to be lower than detection limits. Lead concentration in the samples analyzed varied between N.D. and 12.66 +/- 0.68 ng/mL. The highest concentration of arsenic was determined as 11.54 +/- 2.79 ng/mL. Accuracy of the methods was verified by using a certified reference material namely Trace Element in Water, 1643e. Results found for As, Cd, and Pb in reference materials were in satisfactory agreement with the certified values.
dc.identifier.doi10.1155/2013/824817
dc.identifier.issn2314-4920
dc.identifier.issn2314-4939
dc.identifier.orcid0000-0001-9746-3682
dc.identifier.scopus2-s2.0-84876926766
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1155/2013/824817
dc.identifier.urihttps://hdl.handle.net/11508/56416
dc.identifier.volume2013
dc.identifier.wosWOS:000313506800001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherHindawi Ltd
dc.relation.ispartofJournal of Spectroscopy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectAtomic-Absorption-Spectrometry
dc.subjectSolid-Phase Extraction
dc.subjectNeuronal Apoptosis
dc.subjectDrinking-Water
dc.subjectSoft Drinks
dc.subjectLead
dc.subjectCadmium
dc.subjectCancer
dc.subjectPreconcentration
dc.subjectContamination
dc.titleDetermination of As, Cd, and Pb in Tap Water and Bottled Water Samples by Using Optimized GFAAS System with Pd-Mg and Ni as Matrix Modifiers
dc.typeArticle

Dosyalar