Temperature distributions in boreholes of a vertical ground-coupled heat pump system

dc.contributor.authorEsen, Hikmet
dc.contributor.authorInalli, Mustafa
dc.contributor.authorEsen, Yuksel
dc.date.accessioned2026-08-12T17:45:45Z
dc.date.issued2009
dc.departmentFırat Üniversitesi
dc.description.abstractThe objective of this study is to show the temperature distribution development in the borehole of the ground-coupled heat pump systems (GCHPs) with time. The time interval for the study is 48 h. The vertical GCHP system using R-22 as refrigerant has a three single U-tube ground heat exchanger (GHE) made of polyethylene pipe with a 40 mm outside diameter. The GHE was placed in a vertical borehole (VB) with 30 (VB1). 60 (VB2) and 90 (VB3) m depths and 150 mm diameters. The experimental results were obtained in cooling and heating seasons of 2006-2007. A two-dimensional finite element model (FEM) was developed to simulate temperature distribution development in the soil surrounding the GHEs of GCHPs operating in the cooling and the heating modes. The finite element modelling of the GCHP system was performed using the ANSYS code. The FEM incorporated pipes, the grout and the surrounding formation. From the cases studied, this approach appears to be the most promising for estimation the temperature distribution response of GHEs to thermal loading. (C) 2009 Elsevier Ltd. All rights reserved.
dc.description.sponsorshipScientific Research Projects Management Council of the Firat University (FUBAP) [2005/1153]; Scientific and Technological Research Council of Turkey (TUBITAK) [106Y188]
dc.description.sponsorshipThe authors gratefully acknowledge the financial support from the Scientific Research Projects Management Council of the Firat University (FUBAP) for this study performed under project with grant no. 2005/1153 and the Scientific and Technological Research Council of Turkey (TUBITAK) for its financial support through contract no. 106Y188 (2006-2007).
dc.identifier.doi10.1016/j.renene.2009.04.032
dc.identifier.endpage2679
dc.identifier.issn0960-1481
dc.identifier.issue12
dc.identifier.orcid0000-0002-6260-4948
dc.identifier.orcid0000-0001-8802-8080
dc.identifier.scopus2-s2.0-68049131354
dc.identifier.scopusqualityQ1
dc.identifier.startpage2672
dc.identifier.urihttps://doi.org/10.1016/j.renene.2009.04.032
dc.identifier.urihttps://hdl.handle.net/11508/60815
dc.identifier.volume34
dc.identifier.wosWOS:000269711300018
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofRenewable Energy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectGround heat exchanger
dc.subjectHeat pump
dc.subjectHeating
dc.subjectCooling
dc.subjectFinite element
dc.subjectBorehole
dc.titleTemperature distributions in boreholes of a vertical ground-coupled heat pump system
dc.typeArticle

Dosyalar