Mixed convection in a lid-driven cavity with partially heated porous block

dc.contributor.authorColak, Eren
dc.contributor.authorEkici, Ozgur
dc.contributor.authorÖztop, Hakan Fehmi
dc.date.accessioned2026-08-12T18:06:54Z
dc.date.issued2021
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, the lid-driven cavity problem is investigated under mixed convection conditions by using Finite Volume Method (FVM). A porous block is placed in the middle of the domain with 0.1 porosity. A heater is placed on the edge of the porous block to imitate a local porous heater. In order to investigate the effects of the heater position on the problem physics, the heater is located in 4 different directions (left, right, top bottom) and 3 different orientations (clockwise, counterclockwise and middle). Mixed convection conditions are provided by three different Richardson numbers, 0.1 <= Ri <= 10 and porous block properties are applied by employing 4 different Darcy numbers 10(-7) <= Da <= 10(-1). It is observed that Darcy number can be used to control the vortex formation in the domain under specific configurations. Decrease in Darcy number can increase the average Nusselt number drastically, up to 10 times increase. Heater orientation can be used to control the heat transfer effectiveness, vortex shape and size. Heater orientation can increase the average Nusselt number by 324%. It is also shown that both heater location and orientation show a non-monotonic behavior for different flow parameters.
dc.identifier.doi10.1016/j.icheatmasstransfer.2021.105450
dc.identifier.issn0735-1933
dc.identifier.issn1879-0178
dc.identifier.orcid0000-0002-8900-1485
dc.identifier.orcid0000-0002-1370-7190
dc.identifier.scopus2-s2.0-85108965426
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.icheatmasstransfer.2021.105450
dc.identifier.urihttps://hdl.handle.net/11508/62499
dc.identifier.volume126
dc.identifier.wosWOS:000685644100004
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofInternational Communications in Heat and Mass Transfer
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectMixed convection
dc.subjectOpenFOAM
dc.subjectLid-driven cavity
dc.subjectPorous media
dc.subjectHeater orientation
dc.titleMixed convection in a lid-driven cavity with partially heated porous block
dc.typeArticle

Dosyalar