The effect of storage time on dislocation resistance of core material to root canal sealer in standardized root canals: A laboratory study

dc.contributor.authorGök, Tuba
dc.contributor.authorÇankaya, Güzide
dc.contributor.authorŞen, Bilge Hakan
dc.date.accessioned2026-08-12T16:07:47Z
dc.date.issued2024
dc.departmentFırat Üniversitesi
dc.description.abstractPurpose: To evaluate the effect of storage time on the dislocation resistance of core material to root canal sealer in standardized artificial root canals. Methods: A single root canal with a round shape was selected using cone-beam computed tomography imaging, and root canal treatment was performed. The root was scanned with micro-computed tomography, and the data were exported as a stereolithography file. Forty artificial roots were manufactured using 3D printing technology. The artificial root canals were obturated using a single cone technique. The roots were divided into two groups according to the storage time of filled roots: 7 days and 30 days (n = 20), and stored at 37°C and 100% humidity. After each storage period, 2-mm sections were taken from the middle part of the roots. The sections were tested on a universal testing machine. The dislocation resistances (MPa) were calculated, and the data were analyzed using the Shapiro–Wilk test and independent samples t-test (? = .05). Results: The dislocation resistance of the filling material was significantly higher in the 30-day storage time group compared to the 7-day group (p < .05). Conclusion: The storage time of the root fillings affected the dislocation resistance in the standardized experimental setup with artificial roots. © 2024 Turkish Endodontic Society.
dc.identifier.doi10.14744/TEJ.2023.96158
dc.identifier.endpage27
dc.identifier.issn2459-1726
dc.identifier.issue1
dc.identifier.scopus2-s2.0-105026577656
dc.identifier.scopusqualityN/A
dc.identifier.startpage21
dc.identifier.trdizinid1342295
dc.identifier.urihttps://doi.org/10.14744/TEJ.2023.96158
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1342295
dc.identifier.urihttps://hdl.handle.net/11508/40897
dc.identifier.volume9
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherTurkish Endodontic Society
dc.relation.ispartofTurkish Endodontic Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_Scopus_20260511
dc.subjectArtificial root canal; dislocation resistance; micro-computed tomography; push-out test; storage time
dc.titleThe effect of storage time on dislocation resistance of core material to root canal sealer in standardized root canals: A laboratory study
dc.typeArticle

Dosyalar