The effect of storage time on dislocation resistance of core material to root canal sealer in standardized root canals: A laboratory study
| dc.contributor.author | Gök, Tuba | |
| dc.contributor.author | Çankaya, Güzide | |
| dc.contributor.author | Şen, Bilge Hakan | |
| dc.date.accessioned | 2026-08-12T16:07:47Z | |
| dc.date.issued | 2024 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | Purpose: To evaluate the effect of storage time on the dislocation resistance of core material to root canal sealer in standardized artificial root canals. Methods: A single root canal with a round shape was selected using cone-beam computed tomography imaging, and root canal treatment was performed. The root was scanned with micro-computed tomography, and the data were exported as a stereolithography file. Forty artificial roots were manufactured using 3D printing technology. The artificial root canals were obturated using a single cone technique. The roots were divided into two groups according to the storage time of filled roots: 7 days and 30 days (n = 20), and stored at 37°C and 100% humidity. After each storage period, 2-mm sections were taken from the middle part of the roots. The sections were tested on a universal testing machine. The dislocation resistances (MPa) were calculated, and the data were analyzed using the Shapiro–Wilk test and independent samples t-test (? = .05). Results: The dislocation resistance of the filling material was significantly higher in the 30-day storage time group compared to the 7-day group (p < .05). Conclusion: The storage time of the root fillings affected the dislocation resistance in the standardized experimental setup with artificial roots. © 2024 Turkish Endodontic Society. | |
| dc.identifier.doi | 10.14744/TEJ.2023.96158 | |
| dc.identifier.endpage | 27 | |
| dc.identifier.issn | 2459-1726 | |
| dc.identifier.issue | 1 | |
| dc.identifier.scopus | 2-s2.0-105026577656 | |
| dc.identifier.scopusquality | N/A | |
| dc.identifier.startpage | 21 | |
| dc.identifier.trdizinid | 1342295 | |
| dc.identifier.uri | https://doi.org/10.14744/TEJ.2023.96158 | |
| dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/1342295 | |
| dc.identifier.uri | https://hdl.handle.net/11508/40897 | |
| dc.identifier.volume | 9 | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | TR-Dizin | |
| dc.language.iso | en | |
| dc.publisher | Turkish Endodontic Society | |
| dc.relation.ispartof | Turkish Endodontic Journal | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_Scopus_20260511 | |
| dc.subject | Artificial root canal; dislocation resistance; micro-computed tomography; push-out test; storage time | |
| dc.title | The effect of storage time on dislocation resistance of core material to root canal sealer in standardized root canals: A laboratory study | |
| dc.type | Article |







