CT-guided lung biopsy: diagnostic accuracy and complication rates of biopsy techniques

dc.contributor.authorDeniz, Muhammed Akif
dc.contributor.authorCakir, Caglayan
dc.contributor.authorKilinc, Fatth
dc.contributor.authorKurt, Osman
dc.contributor.authorTas Deniz, Zelal
dc.date.accessioned2026-08-12T17:06:54Z
dc.date.issued2022
dc.departmentFırat Üniversitesi
dc.description.abstractObjective: We aimed to evaluate the diagnostic accuracy and complication rates of computed tomography (CT)-guided core needle biopsy and fine needle aspiration biopsy (FNAB). Materials and Methods: Patients who underwent CT-guided lung mass biopsy were included. The patients were evaluated in terms of age, gender, lesion diameter, lesion localization, depth of the mass, type of biopsy procedure (core needle biopsies and FNAB). Results: The accuracy rate of FNAB in diagnostic material was found to be 100% in terms of benign, malignant and all lesions. The specificity and sensitivity of FNAB was found to be 100%. The diagnostic accuracy rate of core needle biopsy was found to be 70% in benign lesions, 100% in malignant lesions. The specificity of core needle biopsy was 90% and sensitivity 100%. There was no statistically significant difference between the two biopsy techniques in terms of complications. Conclusion: In conclusion, we found that the diagnostic rates of FNAB and core needle biopsy were close in malignant lesions, the diagnostic rate of core needle biopsy was higher in benign lesions, and there was no difference in terms of complications in both biopsy techniques.
dc.identifier.doi10.5472/marumj.1120552
dc.identifier.endpage224
dc.identifier.issn1309-9469
dc.identifier.issue2
dc.identifier.orcid0000-0002-9586-2425
dc.identifier.orcid0000-0003-4164-3611
dc.identifier.scopus2-s2.0-85131804769
dc.identifier.scopusqualityQ4
dc.identifier.startpage219
dc.identifier.urihttps://doi.org/10.5472/marumj.1120552
dc.identifier.urihttps://hdl.handle.net/11508/49445
dc.identifier.volume35
dc.identifier.wosWOS:000806472400016
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherMarmara Univ, Fac Medicine
dc.relation.ispartofMarmara Medical Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectLung
dc.subjectMass
dc.subjectTransthoracic biopsy
dc.subjectComputed tomography
dc.titleCT-guided lung biopsy: diagnostic accuracy and complication rates of biopsy techniques
dc.typeArticle

Dosyalar