Biomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures

dc.contributor.authorAksakal, Bunyamin
dc.contributor.authorGurger, Murat
dc.contributor.authorSay, Yakup
dc.contributor.authorYilmaz, Erhan
dc.date.accessioned2026-08-12T17:04:14Z
dc.date.issued2014
dc.departmentFırat Üniversitesi
dc.description.abstractPurpose: Biomechanical comparison of straight DCP and helical plates for fixation of transversal and oblique tibial bone fractures were analyzed and compared to each other by axial compression, bending and torsion tests. Method: An in vitro osteosynthesis of transverse (TF) and oblique bone fracture (OF) fixations have been analysed on fresh sheep tibias by using the DCP and helical compression plates (HP). Results: Statistically significant differences were found for both DCP and helical plate fixations under axial compression, bending and torsional loads. The strength of fixation systems was in favor of DC plating with exception of the TF-HP fixation group under compression loads and torsional moments. The transvers fracture (TF) stability was found to be higher than that found in oblique fracture (OF) fixed by helical plates (HP). However, under torsional testing, compared to conventional plating, the helical plate fixations provided a higher torsional resistance and strength. The maximum stiffness at axial compression loading and maximum torsional strength was achieved in torsional testing for the TF-HP fixations. Conclusion: From in vitro biomechanical analysis, fracture type and plate fixation system groups showed different responses under different loadings. Consequently, current biomechanical analyses may encourage the usage of helical HP fixations in near future during clinical practice for transverse bone fractures.
dc.identifier.doi10.5277/ABB-00045-2014-01
dc.identifier.endpage74
dc.identifier.issn1509-409X
dc.identifier.issue4
dc.identifier.orcid0000-0002-7510-7203
dc.identifier.orcid0000-0003-1066-3337
dc.identifier.orcid0009-0007-7644-5785
dc.identifier.orcid0000-0003-4844-9387
dc.identifier.orcid0000-0001-5005-8516
dc.identifier.pmid25597271
dc.identifier.scopus2-s2.0-84920868914
dc.identifier.scopusqualityQ4
dc.identifier.startpage67
dc.identifier.urihttps://doi.org/10.5277/ABB-00045-2014-01
dc.identifier.urihttps://hdl.handle.net/11508/48641
dc.identifier.volume16
dc.identifier.wosWOS:000348507400008
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWroclaw Univ Technology
dc.relation.ispartofActa of Bioengineering and Biomechanics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectstraight DC plate
dc.subjecthelical plate
dc.subjectbiomechanics
dc.subjectfixation
dc.subjectbone fractures
dc.titleBiomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures
dc.typeArticle

Dosyalar