Experimental and Numerical Investigation of the Effect of Turbulator on Heat Transfer in a Concentric-type Heat Exchanger

dc.contributor.authorBudak, N.
dc.contributor.authorYucel, H. L.
dc.contributor.authorArgunhan, Z.
dc.date.accessioned2026-08-12T17:32:41Z
dc.date.issued2016
dc.departmentFırat Üniversitesi
dc.description.abstractThis article experimentally and numerically analyzes the effect of turbulators with different geometries (Type I, Type II, Type III, and Type IV) located at the inlet of the inner pipe in a concentric-type heat exchanger. Experiments were performed at parallel-flow conditions in the same and opposite directions to investigate the impact of manufactured turbulators on heat transfer and pressure drop. In the numerical study, ANSYS 12.0 Fluent code program was used, and basic protection equations were solved in the steady-state, three-dimensional, and turbulence-flow conditions. Results were obtained from numerical analysis conducted at different flow values of air (7, 8, 9, 10, 11, and 12m(3)/h). The distribution of temperature, velocity, and pressure was demonstrated as a result of numerical analyses. Experimental and numerical results were compared, and it was observed that they were in conformity with each other. When the data obtained from the analyses were examined, the highest heat transfer, pressure drop, and friction factor increase were detected to be in the Type IV turbulator.
dc.description.sponsorshipFirat University Research Foundation (FUBAP) [2065]
dc.description.sponsorshipThe authors wish to thank the Firat University Research Foundation (FUBAP) for financial support under project number 2065.
dc.identifier.doi10.1080/08916152.2014.976723
dc.identifier.endpage336
dc.identifier.issn0891-6152
dc.identifier.issn1521-0480
dc.identifier.issue3
dc.identifier.orcid0000-0002-2203-0177
dc.identifier.scopus2-s2.0-84953257868
dc.identifier.scopusqualityQ1
dc.identifier.startpage322
dc.identifier.urihttps://doi.org/10.1080/08916152.2014.976723
dc.identifier.urihttps://hdl.handle.net/11508/56740
dc.identifier.volume29
dc.identifier.wosWOS:000373781500003
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTaylor & Francis Inc
dc.relation.ispartofExperimental Heat Transfer
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectturbulator
dc.subjectnumerical analysis
dc.subjectheat transfer enhancement
dc.subjectconcentric heat exchanger
dc.titleExperimental and Numerical Investigation of the Effect of Turbulator on Heat Transfer in a Concentric-type Heat Exchanger
dc.typeArticle

Dosyalar